The retriangulation
Trig pillars were built to remeasure Great Britain between 1936 and 1962.
Before the pillars, Ordnance Survey's mapping rested on the Principal Triangulation, a set of observations gathered piecemeal between 1783 and 1853. After the First World War it could not support the more accurate mapping the country needed. OS began again with a single, consistent network: the retriangulation of Great Britain.
The work started on 18 April 1936 at a concrete pillar in a field at Cold Ashby in Northamptonshire. The last observation was made at Thorny Gale in Cumbria on 4 June 1962. Brigadier Martin Hotine led the project and designed the pillar, which is why the standard tapered concrete type is sometimes called a Hotine pillar. Around 6,500 pillars were built, and the finished retriangulation had more than 30,000 coordinated points. It provided the fixed positions on which the National Grid was built.
Anatomy of a pillar
Each pillar was a stable stand for measuring angles to its neighbours.
Triangulation fixes positions by measuring the angles between points that can see each other. That is why pillars sit on summits and open high ground with long views. A surveyor set a theodolite on the top plate, levelled it over a reference mark beneath the pillar, and measured the angles to surrounding stations.
- SpiderThe brass fitting on top, with three grooves 120 degrees apart. It centres an instrument exactly over the station every time.
- Flush bracketThe numbered metal plate on the side of most, but not all, pillars. It is a height mark, not part of the triangulation.
- VanessaA round pillar, found mainly in Scotland, named after the maker of the cardboard tubes used to cast them. The design saved material and transport.
On OS Explorer maps a trig pillar appears as a small blue triangle with a dot in the middle. A topographic map uses such marks as fixed references among the contours and paths.
Heights, not positions
The flush bracket marks a height above Ordnance Datum Newlyn.
A pillar marks an accurate horizontal position. The flush bracket does a different job: it is one of the more important height control points, levelled to Ordnance Datum Newlyn, which is mean sea level as determined at Newlyn in Cornwall. Flush brackets are also set into walls and buildings, and they are related to the cut benchmarks found on churches, bridges and houses.
For a pillar with a flush bracket, the height reference is the top of the arrowhead on the plate, not the ground or the top of the pillar. OS records also note the difference between the bracket and the ground at the base, and the hill's highest point where that differs. A trig pillar is therefore not always on the true summit, and the summit height on a map need not be the pillar's height. Why vertical datums change altitude numbers explains why a GPS altitude read beside the pillar may also differ.
Status today
Trig pillars are now redundant for national mapping.
OS's modern equivalent is OS Net, a network of 110 permanent GNSS receivers that lets surveyors position new map detail to within a few centimetres. OS describes the traditional pillar as obsolete in its original role and says most of its old height marks are redundant for national mapping. It still maintains about 190 fundamental benchmarks as its primary height network, but those are separate marks, each with an underground chamber holding its master reference.
In the early 1990s OS decided it no longer needed most pillars. An adoption scheme launched in 1992 was later abandoned, though volunteers still look after some sites informally. Hundreds of pillars have been lost to development, farming and coastal erosion; OS puts the number still standing at around 5,500. In April 2026 the Twentieth Century Society applied to Historic England to list the first and last pillars, at Cold Ashby and Thorny Gale, noting that none was on a national heritage list.
Use on the hill
A pillar is still a reliable landmark, but not a guarantee of anything else.
- Confirm
Use it to check position.
A pillar is a mapped point you can identify on the ground, which makes it a good place to confirm where you are and take a bearing for the next leg.
- Summit
Check whether it is the top.
Look at the spot heights and contours. The highest ground may be a cairn or rise a short distance away.
- Access
Do not treat a pillar as a public destination.
Many stand on farmland or private estates. Reaching one depends on the access rules for the land around it. How to check route access sets out that check.
Trig pillars were built to fix the map. Today they mostly help walkers fix their place on it.
When the map gives you rings but no surveyed summit label, use their height sequence to distinguish a hill from a hollow.
Sources & scope
What this answer is based on.
- Ordnance Survey: a history of the trig pillar
- Ordnance Survey: trig pillar facts and features
- Ordnance Survey: benchmarks, flush brackets and trig pillars
- Twentieth Century Society: listing bid for the first and last pillars (2026)
Counts and dates are from Ordnance Survey. Ordnance Survey does not publish a current maintenance policy for individual pillars; the adoption history is as reported by the Twentieth Century Society in April 2026.